7-channel MR coil array for concurrent TMS/fMRI (not stock item)
A radio frequency coil for magnetic resonance investigations of the human head in vivo.
Intended for use with a compatible 3T MR Scanner and in combination with MRi-B91 or MRi-B91 Air Cooled coils.

Additional Front part for MRi-Coil Holder (not stock item)
The front part is the part of the Coil holder actually holding the coil.

Coil MRi-B91
The coil is suitable for focused stimulation. Designed for use in MRI scanners up to 4 Tesla with biphasic waveform standard mode. Symmetrical placed inside the housing so the magnetic field on both sides is equal. Compatible with R30 & X100. Not for use with power mode or any other waveforms. Dimensions of transducer head: 175 x 142 x 30 mm

Coil MRi-B91 Air Cooled
Similar to above, but with air cooling that is to be connected to a wall outlet of compressed air (the hospital's centralised compressed air system).

Double Power Line Filter for MRi (not stock item)
Intended for MRi installations where two scanners are located closed to each other. The Double Filter ensures that crosstalk from one scanner room is not transported out through the MRi-coil installation and to the scanner room next by. The Double Power Line Filter is designed with one Filter box inside the scanner room and with one Filter box outside the scanner room to filtering signals in both directions.

EEG Noise Filter for MagPro R20 and MagPro Compact
This is an upgrade to the MagPro device in order to be optimised for EEG

EEG Noise Filter for MagPro R30 and X100
This is an upgrade to the MagPro device in order to be optimised for EEG

Emergency Stop for MRi (and for general use)
Emergency stop for the patient to have inside the scanner. The patient can disable the MagPro at any time.

MagPro Dynamic and Standard Leakage Current Reduction for MRi
A circuitry added to the MagPro stimulator to eliminate/reduce artefacts during charging of the capacitor inside MagPro allowing MRi-recording very close to the stimulation. The DC-leakage component when not charging has been reduced to below 1uA with this option.

MagPro Standard Leakage Current Reduction for MRi
Minimum requirements for all MagPro G3 stimulators to be used in MRi environment along with the MRi-B91 coils.
Most customers will choose the more extended solution:
MagPro Dynamic and Standard Leakage Current Reduction for MRi (part no. 9016E1051)

MagPro Ugrade for Emergency Stop (for non-MRi use)
To allow the patient or the operator to quickly stop the MagPro from a distance, the Emergency Stop 9016C074- can be used.
For supporting connection of the Emergency Stop to the MagPro front panel, an upgrade of MagPro must be ordered.

MagPro XP Leakage Current Reduction for Mri
A circuitry added to the MagPro XP stimulator to eliminate/reduce artefacts during charging of the capacitor inside MagPro allowing MRi-recording very close to the stimulation. The DC-leakage component when not charging has been reduced to below 1uA with this option.

MRi-Coil Holder (for Siemens Magnetom Trio scanner) (not stock item)
Holding device used for MRi-coil placement inside a MR scanner. For easy, stable and precise positioning of the MRi-coil.
6 degrees of freedom (X, Z and 4 angular adjustments) with scales. 1 grip fine tuning to ensure coil is placed perpendicular on the scalp.

Power Line filter for MRi
Without a proper filtering of all cables entering the MRi room it may not be possible to obtain proper MRi images.

Remote Control for MRi (and for general use)
The MagPro Remote Control provides the user with the possibility to operate the MagPro from a distance. With the MagPro Remote Control it is possible to enable MagPro, make single stimuli and to set the output power from a distance. The LED indicates whether the Stimulator is enabled or disabled.